CEM Corp - MDS-2000 Microwave Laboratory Digestion System

CEM Corp - MDS-2000 Microwave Laboratory Digestion System

Price £SOLD

The Microwave Digestion System, Model MDS-2000, is designed for laboratory use in digesting, dissolving, hydrolyzing, or drying a wide range of materials. Its primary purpose is the rapid preparation of samples for analysis by atomic absorption (AA) and inductively coupled plasma (ICP) emission spectroscopy and gas or liquid chromatography.

The MDS-2000 Microwave Laboratory Digestion System consists of

  • a microwave power system with operator selectable output of 0 - 630 watts ±50 watts in 1 percent increments.
  • a fluoropolymer-coated microwave cavity.
  • a cavity exhaust fan with programmable speed in 10 percent increments.
  • exhaust tubing to vent fumes.
  • a digital computer programmable for thirty multistep programs consisting of up to five stages each.
  • a direct drive alternating turntable system.
  • four inlet/outlet ports to accommodate temperature and/or pressure measurement and control lines.
  • three door safety interlocks and an interlock monitoring system to prevent microwave emission when door is open.

 

The MDS-2000 uses microwave energy to heat samples. Compounds such as water and other polar liquids absorb microwave energy rapidly. A sample placed inside a microwave transparent vessel with a polar liquid or ionic solution (usually acid) is subjected to rapid heating and in the case of a sealed vessel, elevated pressures, causing the sample to digest or dissolve in a short time.

The MDS-2000 microwave sample preparation system is operated under full microprocessor control with constant monitoring of the door safety interlocks, pressure, and if required temperature, within the digestion vessel. An exhaust tube to vent fumes is permanently connected to an adjacent fume cupboard.

Includes user manual

CEM Corp - MDS-2000 Microwave Laboratory Digestion System Dimensions

Height 500mm
Width 470mm
Depth 650mm

Weight 51kg

240V

Please contact us if you have any questions or require further information about this CEM Corp - MDS-2000 Microwave Laboratory Digestion System

All information given on this website is correct at the time of publication. However in the interests of technical progress, design specifications are subject to change without notice.  Accordingly, data given herein should be regarded as a general guide only and does not form part of any contract.  All goods are supplied in accordance with our standard terms and conditions of sale.