EquipmentLaboratoryMDH Microflow Biological Safety Fume Cabinet Class 2

MDH Microflow Biological Safety Fume Cabinet Class 2



STOCK REF#: G337


MDH Contamination Control Microflow Biological Safety Fume Cabinet

Ducted Class 2 Cabinet

Supplied with ducting as per images.

Model M51424/1

The microprocessor controlled membrane keypad allows straightforward operation of fan
switching, lights and safety features. The cabinet has audible and visual alarms for air
velocity and filter change ensuring maximum protection at all times.


The cabinet has a unique sliding/ hinged door mechanism that provides uninterrupted
access and a 100% seal for bio-decontamination so no closing panel is needed.

During bio-decontamination the cabinet operates at negative pressure eliminating leaks to
the atmosphere, gas passes through all filters to ensure efficient removal of all
contaminating particles. Shorter cycle times for bio-decontamination means minimal
downtime in the laboratory

1994 Build

In excellent clean condition fitted with Microflow Formalin Vaporizer

Fitted with Pre-used Main and exhaust HEPA filters

Glass working height:     200mm
Front screen:                    Laminated glass
Inner liner:                        Crevice free 316 stainless steel
Work area:                        Recessed 316 stainless steel tray
Construction:                   Mild steel with powder coating
Noise level:                     <65 dBA at 1m
Lighting:                           1000 lux at work surface
Filters:                               99.999% HEPA - DOP tested

Serial # 94/07/2/003

Dims 74cm (D) x 156 cm (W) x 156 cm (H)

Currently fitted with a non-fan exhaust duct however we have a similar exhaust duct with
fan that can be supplied as an alternate or additional item

POA - Contact Us



The pictures you are looking at are of the MDH Microflow Biological Safety Fume Cabinet Class 2. This is the actual item you are buying, they are not downloaded or copied from any other source.
All information given on this website is correct at the time of publication. However in the interests of technical progress, design specifications are subject to change without notice. Accordingly, data given herein should be regarded as a general guide only and does not form part of any contract. All goods are supplied in accordance with our standard terms and conditions of sale. If you need more information on using this equipment check out The Laboratory Encyclopedia.
Back Top
Services | Shipping | About | FAQ | Terms & Conditions | Testimonials | Links | Contact Us |
Content

LoginSafe to pay online

Or use an external account